Share:


Experimental behaviour of composite girders with steel undulating web and thin‐walled shear connectors Hilti Stripcon

    Jan Motak Affiliation
    ; Josef Machacek Affiliation

Abstract

Two tests of real‐size composite steel and concrete girders are described. The girders had spans 7,5 m, thin‐walled undulating webs (WT girders) and concrete deck 120/1500 mm concreted into profile steel sheeting TR 60/235/0,75. Thin‐walled shear connectors Hilti Stripcon were used and fastened via powder actuated fasteners. Setup of the tests, relevant instrumentation and measuring procedure are presented. The girder tests supplemented large series of push tests of connectors Stripcon performed at CTU in Prague. One of the composite girders was designed with full‐shear connection while the second one with extremely low partial shear connection (44%). Simple preliminary linear calculations proved that experimental strength capacities of the girders are in good agreement with the calculated values, however, the deflection are due to flexibility of the connectors higher. Buckling shear capacity of the undulating webs in both tests was higher than shear at collapse of the girders. Another test dealing with interaction of web buckling in shear and Stripcon shear connection is under progress. Comparison of theoretical and experimental results is performed and recommendations for practical design are presented.


First Published Online: 14 Oct 2010

Keyword : composite girder, shear connector, Stripcon, undulating web, powder actuated fastener, test

How to Cite
Motak, J., & Machacek, J. (2004). Experimental behaviour of composite girders with steel undulating web and thin‐walled shear connectors Hilti Stripcon. Journal of Civil Engineering and Management, 10(1), 45-49. https://doi.org/10.3846/13923730.2004.9636285
Published in Issue
Mar 31, 2004
Abstract Views
345
PDF Downloads
254
Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.